ALAT MONITORING PEMAKAIAN ENERGI PADA LAYANAN PENYAMBUNGAN SEMENTARA 1 FASA BEBASIS IOT (INTERNET OF THING) DI PLN ULP NGAWI

Awaliah, Awaliah (2023) ALAT MONITORING PEMAKAIAN ENERGI PADA LAYANAN PENYAMBUNGAN SEMENTARA 1 FASA BEBASIS IOT (INTERNET OF THING) DI PLN ULP NGAWI. Skripsi (S1) thesis, Universitas Muhammadiyah Ponorogo.

[img] Text (Surat Persetujuan Unggah Karya Ilmiah)
1. Surat Persetujuan Unggah Karya Ilmiah.pdf

Download (805kB)
[img] Text
HALAMAN DEPAN.pdf

Download (2MB)
[img] Text (BAB 1)
BAB I.pdf

Download (97kB)
[img] Text (BAB II)
BAB II.pdf
Restricted to Repository staff only

Download (300kB)
[img] Text (BAB III)
BAB III.pdf
Restricted to Repository staff only

Download (267kB)
[img] Text (BAB IV)
BAB IV.pdf
Restricted to Repository staff only

Download (1MB)
[img] Text (BAB V)
BAB V.pdf
Restricted to Repository staff only

Download (19kB)
[img] Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (87kB)
[img] Text (LAMPIRAN)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (13kB)
[img] Text (SKRIPSI FULL TEXT)
SKRIPSI FULL TEXT.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

One of the facilities from PLN for customers is the addition of power within a certain period of time for customer events that require more power than their contracted power subscription. PLN will install a special kWh meter, called a party kWh meter, to calculate the customer's power usage during the event. However, due to the amount of work that exists in PLN, and the number of officers that are not proportional to the demand for parties, sometimes PLN does not immediately disconnect and dismantle the party material, which can be detrimental to customers because the bill on the party kWh meter continues to be calculated without them knowing and causes problems for PLN. Therefore, the following research was conducted with the aim that this tool can monitor energy usage by customers and PLN automatically using the PZEM-004T energy sensor module with an average test result of no more than 5%. This tool can also provide supplementary billing information to customers and PLN when kWh usage exceeds emin with a maximum delivery delay of 3 seconds. In addition to monitoring energy consumption and supplementary bills, this tool can automatically disconnect remotely when the party is over with a relay disconnection delay of no more than 5 seconds.

Item Type: Thesis (Skripsi (S1))
Uncontrolled Keywords: PLN, kWh, Pesta, Monitoring, Pemutus
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering
Depositing User: ft . userft
Date Deposited: 12 Sep 2023 03:28
Last Modified: 12 Sep 2023 03:28
URI: http://eprints.umpo.ac.id/id/eprint/12392