STUDI EKSPERIMENTAL PENGARUH VARIASI JUMLAH LUBANG VENTILASI PADA TUTUP TROMOL TERHADAP PENURUNAN SUHU TROMOL BELAKANG SEPEDA MOTOR



PRAYOGA, RICKI ACHMAD (2026) STUDI EKSPERIMENTAL PENGARUH VARIASI JUMLAH LUBANG VENTILASI PADA TUTUP TROMOL TERHADAP PENURUNAN SUHU TROMOL BELAKANG SEPEDA MOTOR. S1 thesis, UNIVERSITAS MUHAMMADIYAH PONOROGO.

Text (SURAT UNGGAH KARYA)
SURAT UNGGAH KARYA.pdf

Download (957kB)
Text (HALAMAN JUDUL)
HALAMAN JUDUL.pdf

Download (2MB)
Text (BAB I)
BAB I.pdf

Download (112kB)
Text (BAB II)
BAB II.pdf
Restricted to Repository staff only

Download (336kB)
Text (BAB III)
BAB III.pdf
Restricted to Repository staff only

Download (367kB)
Text (BAB IV)
BAB IV.pdf
Restricted to Repository staff only

Download (402kB)
Text (BAB V)
BAB V.pdf
Restricted to Repository staff only

Download (68kB)
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (143kB)
Text (LAMPIRAN)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (1MB)
Text (SKRIPSI FULL TEXT)
SKRIPSI FULL TEXT.pdf
Restricted to Repository staff only

Download (5MB)

Abstract

ABSTRACT

Drum brake systems generate heat due to friction between the brake lining and the drum during braking. If the heat cannot be dissipated optimally, the drum temperature will increase and potentially reduce braking performance. This study aims to determine the effect of variations in the number of ventilation holes in the drum cover on the rear drum temperature of a motorcycle. The method used was an experimental method with variations of no ventilation holes, 4 holes, 6 holes, 8 holes, and 10 ventilation holes. Temperature measurements were conducted after the braking process for each variation, and the results were visualized as temperature distribution. The results showed that increasing the number of ventilation holes could reduce the drum temperature. The variation without ventilation holes produced the highest average temperature of 39.1 °C, while the variation with 10 ventilation holes produced the lowest average temperature of 34.4 °C. The temperature distribution visualization showed that the highest temperature occurred in the drum wall area that was in frictional contact with the brake lining. Therefore, the addition of ventilation holes in the drum cover was proven to improve heat dissipation, resulting in a lower operating temperature of the drum.

Keywords: Drum Brake, Ventilation Holes, Drum Temperature, Temperature Distribution

Dosen Pembimbing: SUDARNO, SUDARNO and FADELAN, SUDARNO | 05076801, 0709056101
Item Type: Thesis (S1)
Uncontrolled Keywords: Keywords: Drum Brake, Ventilation Holes, Drum Temperature, Temperature Distribution
Subjects: L Education > L Education (General)
Divisions: Faculty of Engineering > Department of Machine Engineering
Depositing User: Ricki Achmad Prayoga
Date Deposited: 14 Sep 2026 07:25
Last Modified: 14 Sep 2026 07:25
URI: https://eprints.umpo.ac.id/id/eprint/20682